Your browser (Internet Explorer 6) is out of date. It has known security flaws and may not display all features of this and other websites. Learn how to update your browser.
X

Posts tagged ‘thatched’

Post

Hampshire Thatchsayf

Easton

The recent good weather saw TAS out and about spraying thatched roofs across the country with their Thatchsayf Fire Retardant Spray System. First stop was Hampshire for a pair of lovely semi-detached cottages. The thatching was carried out by Ed Goodall last year. During the thatching TAS also installed the Thatch Alert chimney heat monitor system to both chimneys.

Share
Post

Thatchsayf Spray System – Thatch Fire Retardant

Thatchsayf - Fire Retardant

Fire – Causes

A report from fire investigators Burgoynes into the cause of thatch fires revealed ejected embers and sparks as one of the main causes.

Investigations have shown that many thatch fires relate to the use of wood burning stoves and have occurred within 30 minutes of the stove being lit. In addition, some home-owners were found to be using unsuitable materials to get the wood burner/fire started in the first place.

Other causes can increase the risk of the effects from ejected embers or sparks, these include:

Spark Arrestors – If not cleaned at least once a year then soot deposits can build up and ignite causing a fire in their own right, which in turn could cause a thatch fire. A number of fire services recommend the removal of spark arrestors although a wire-mesh bird guard could be installed to deter birds from nesting but still allow the chimney to function efficiently.

Chimney Height – The risk of a thatch fire is further increased when the chimney height has been reduced following many years of re-coating works, this is more common with thatching materials such as long straw.

 

 

 

 

 

Fire Retardant Sprays

The main purpose of a fire retardant is to starve the ignition area of oxygen and therefore delay the spread of flame and the full development of a thatch fire. The idea is to buy more time so that the fire and rescue service have a greater chance of extinguishing the fire before it fully develops.

Thatchsayf Spray System is a water based solution containing fire retardant and intumescent ingredients for the protection of thatched roofing.

This environmentally friendly solution is applied externally to the thatch surface and penetrates the stems of the thatch by up to 75mm, forming a thin protective film on the surface of the thatch stems.

A treated roof will offer protection from a number of fire risks, including sparks, ejected embers, bonfires, Chinese lanterns, fireworks and barbecues.

On exposure to these risks, Thatchsayf Spray System will ‘foam up’ (intumesce) and form a carbonised char, which binds the thatch stems together, cutting off the supply of oxygen to the fire, delaying the spread of flame and lowering the radiated heat output.

The application of Thatchsayf Spray System is undertaken by our fully trained employees using specialist spraying equipment and is normally carried out between March and the end of October. This is due to the high levels of moisture in the air during the winter months.

Once a roof is treated, the homeowner is issued with a Certificate of Completion, which is valid for five years after which re-application is required.

A new build/newly thatched roof offers a good opportunity to treat a roof. However, an existing thatched roof can also be treated as long as it is in good condition. Thatchsayf Spray System can be applied as a standalone product or in addition to having a physical fire barrier system installed.

We suggest you contact your insurance company to check if any discounts are available for taking a proactive approach by treating the roof with a fire retardant spray and fire barriers.

Testing

Thatchsayf Spray System has been tested to vigorous testing by the British Research Establishment (BRE). Further details of testing is available upon request. Thatchsayf Spray System is tested to BS476 Part 3 and achieved the designation of EXT.S.BA

The benefits of Thatchsayf Spray System

  • Fire penetration may be delayed for over 30 minutes with no spread of flame
  • Can be applied to new or existing thatched roofs
  • Contains preservatives
  • Retards bacterial and fungal growth including moss
  • Application is fully certified for 5 years
  • Environmentally friendly
  • May reduce insurance premiums

 

Share
Post

New Meeting room at Thatchers Cider

Thatching Advisory Services - Thatchers Cider

A new meeting room currently being built at Thatchers Cider has been designed to showcase sustainable construction techniques. With that in mind, the Sandford cider maker asked Somerset master thatchers, Dunbar & Bunce to install a new thatched roof.

Passionate about conservation, both Tom and Nigel – together with their team of highly skilled thatchers, provide an extremely knowledgeable and sympathetic approach to both historic buildings as well as modern applications, such as new houses and extensions.

It is being built with a solid oak framework and natural stone walls. Prior to the actual thatching,  the roof  timbers were covered with Thatch Firewall Membrane, which is one of the fire barriers provided by Thatching Advisory Services.

Martin Thatcher, Managing Director says, “Our new meeting room is being built in the heart of a beautiful part of one of our orchards, in a thicket, overlooking a pond. It is an opportunity for us to show how we embrace nature. Beinyears.”

Share
Post

TAS asked to write for Listed Property Owners Club Magazine

Rob Norcott of Thatching Advisory Services was asked by Listed Property Owners’ Club Ltd.  to write an article for latest magazine.

Listed Heritage Magazine is published by the Listed Property Owners’ Club for their members. This is a full colour, perfectly bound A4 production; it is published bi-monthly and distributed to 19,000 listed property owners. The Listed Heritage Magazine includes amongst other things: suppliers directory, members letters, shopping pages, events and properties for sale.

The 4 page piece was centered around the importance of separation in construction on thatched roofs. The article also takes you through common causes of thatch fires, from old or faulty electrical systems through to bonfires or fireworks. It also discusses the various systems and preventive measures available such as Thatch Fire Board System, Thatch Fire Wall System; the use of Thatchbatts® and the Thatchsayf spray.

To see the full article click the link below:

TAS article for Listed Heritage – Issue 95

Share